The VO-FN90CF-PC-AC moves 90 CFM through a 4 in. oval discharge with a built-in backdraft damper, sized for bathrooms up to about 90 sq ft.
It draws 30W at 120V/60Hz and runs at 2.0 sones on a dual ball-bearing motor with a thermal cut-off fuse.
The housing is moulded in V0 flame-retardant ABS. cETL listed for insulated ceilings, and for mounting over a tub or shower on a GFCI-protected circuit. Two-year warranty.
What size bathroom does a 90 CFM fan cover?
About 90 square feet. The Home Ventilating Institute rule is 1 CFM per square foot between 50 and 100 sq ft, so this one covers a room up to roughly 9 ft by 10 ft. Past 100 sq ft, count fixtures instead: 50 CFM each for toilet, shower and tub, 100 for a jetted tub.
One caveat. That 90 CFM is measured at 0.1 in. w.g. A real duct run sits higher, and a fan on existing ductwork may not reach rated airflow at all.
Can a bathroom fan have too much CFM?
Yes, and you'll hear it first. "CFM too great" is the opening entry in this fan's own troubleshooting table for a unit louder than it should be. Oversizing also drags conditioned air out of a tight house faster than it gets replaced. Size to the room.
Checking a fan that's already in? Run a shower. If the room clears in about 15 minutes it's working. The tissue test tells you almost nothing.
Where this fan is listed to go
The housing is V0 flame-retardant ABS, a self-extinguishing grade under UL 94, and the motor carries a thermal fuse. It's cETL listed for insulated ceilings, Type I.C., and over a bathtub or shower on a GFCI-protected circuit. Not every plastic bath fan holds that second listing.
Will it fit your ceiling and your duct?
Cut 10 in. x 10 in. Housing is 11-1/4 in. square by 4 in. deep, grille covers 12-1/4 in. square. On a swap-out, measure the old opening first and confirm the grille still covers it.
Discharge is 4 in. oval, so budget an oval-to-round transition. Don't reduce below 4 in., that adds noise. Keep the first elbow 18 in. clear. Two hard limits: no ceiling insulated above R40, and no dimmer or solid-state speed control.
For the wiring warnings, both mounting methods and the duct routing diagrams, open the Manual (PDF) in the Related documents panel. Send us your unit count per model and we'll quote wholesale, and flag whether the 70 or 100 CFM unit suits the rooms better.