The Adjustable Wall Pack Light 50W aims where a fixed wall pack can't. Its die-cast head swings through a 0-90° arc, so one housing washes a wall face or throws forward across a laneway.
Three wattages (50W/40W/30W) cross with three colour temperatures (3000K/4000K/5000K) for nine field-set outputs, 3600Lm to 6750Lm. Any supply from 120V to 347V.
Bronze die-cast aluminum, IP65, cULus-listed wet location, 4kV surge protection, built-in photocell, 5-year warranty.
How do you set the wattage and colour temperature?
Both switches live inside the fixture, so you set them during installation and not before. Open the driver box, pick 50W, 40W or 30W on the power knob, then pick 3000K, 4000K or 5000K on the CCT switch. That's nine outputs from one part number.
At 50W you get 6000Lm warm, 6750Lm neutral, 6250Lm daylight. At 40W it's 4800Lm, 5400Lm and 5000Lm. At 30W it's 3600Lm, 4050Lm and 3750Lm. One SKU covers a doorway and a loading bay, which cuts what you carry on the truck.
How far does the head adjust?
Zero to 90 degrees. Loosen the Allen screws on the side of the heatsink and rotate the optic, then retighten. Aimed flat it throws forward across a 90° x 110° beam. Rotated down it turns near-cutoff and keeps light off the property next door.
One limit worth knowing before you spec a rebate job. The manual restricts DLC-qualified use to fixtures emitting to the same side, not aimed in different directions across a run. Aim a row consistently and the DLC listing holds.
Does it need a separate photocell?
No. Dusk-to-dawn switching is built in. The sensor switches on below roughly 150 lux and off above 240 lux, with a sub-10-second delay each way so headlights don't cycle it. Mount it where nothing shades the sensor, or it'll hold on through daylight.
Wiring and mounting
Supply conductors must be rated 90°C minimum. The driver accepts anything from 120V to 347V, dims 0-10V, and carries 4kV surge protection built in. IP65 and cULus wet-location rated, running -40°C to +50°C. Standard wall mounting, 4.84 lbs, and a qualified electrician only. Don't mount it in the rain.
For the nine-setting lumen table, the switch diagrams and the nine-step mounting sequence, open the Manual and Spec sheet, and take the IES file if your designer needs photometry. Send us your wattage split and quantity and we'll return a wholesale quote with a 347V compatibility check.