This slim LED exit sign runs 3 hours on battery, an hour past the longest duration any Ontario building can demand. The acrylic panel rotates a full 180 degrees and swaps between three arrow pictograms, so one part number covers every door on the floor.
3.5W draw. 6500K. One continuous 120-347V input. 24-hour recharge. Single or double face.
Thermoplastic housing, cULus-Listed for damp locations, 0.75 kg, backed 5 years.
What are the requirements for exit signage in Canada?
Green and white, with a graphic symbol matching ISO 7010. Ontario's Building Code (Art. 3.4.5.1) requires one wherever the exit serves a building over 2 storeys, an occupant load above 150, or a floor area with a fire escape in the egress route. Internally illuminated signs must stay lit continuously, so never put one on a dimmer. This unit ships three pictograms, so the installer picks direction on site rather than ordering a part number per door.
How long does an exit sign have to stay lit in a power failure?
Between 30 minutes and 2 hours, depending on the building. OBC Art. 3.2.7.4 sets 2 hours for high buildings, 1 hour for Group B occupancies and retirement homes, 30 minutes for everything else. This one is rated for 180 minutes and recharges in 24. It clears the toughest tier with an hour in hand, and that margin is what matters once a battery is five years into service.
One input covers every commercial service voltage
Black to line, white to neutral, green to ground. That's the whole job, anywhere between 120V and 347V. No taps. No jumpers. One stocked part covers 120V, 208V, 240V, 277V and 347V, which matters on multi-tenant retrofits where service voltage changes between units.
Where it fits, and where it doesn't
Surface wall, ceiling or end mounting, each with its own sequence in the manual. Indoor use only per the manual, so read the damp rating as covered and heated, not exterior. The 0°C to 40°C range rules out unheated stairwells, parkades and vestibules. No remote head capacity on this model, so specify a combo unit if you need lamp heads on the same battery.
For the mounting sequences, the pictogram swap and the 3mm screwdriver the top cover needs, open the Manual (PDF), and pull the IES download if your designer wants photometry. Send us your door count and we'll quote it against the duration tier your building falls under.